Inspection and mapping services

Solar & wind energy UAV topographic mapping

Our solar farm inspection drone identifies underperforming panels, wiring faults, and mounting defects using aerial thermal and visual capture, and we survey and map wind energy sites for topography, access roads, crane pads, collection corridors, and construction progress. Findings are tagged to your plant numbering so an O&M crew can walk straight to the flagged module or pad.

What we inspect

01

Panel hotspots & underperformance

Thermal and visual inspection identifies panels running hotter than their neighbors, indicating cell damage, diode failure, or substring issues that reduce string output.

02

Wiring & connection faults

We detect faulty connections, loose wiring, and damaged cables across the array, locating electrical faults that would take hours of manual troubleshooting to find on the ground.

03

Structural mounting issues

Aerial review checks mounting structures, racking, and panel alignment for shifting, damage, or installation defects that affect long-term stability.

04

Vegetation & debris affecting output

We map vegetation growth and debris accumulation that shades panels or blocks airflow, so maintenance crews can clear obstructions before they cut into energy production.

05

Inverter & combiner box areas

Close-up inspection of inverter and combiner box locations captures visible damage, overheating, and connection issues at the points where array output is gathered and converted.

Benefits

  • Covers a full array in a day versus a multi-day manual walkthrough
  • Catches cell and string faults while they are still a small production loss
  • Findings keyed to plant numbering drive a direct repair order
  • Scales from a single block to multi-hundred-megawatt sites
Fault signatures

What aerial inspection finds

PV module inspection from the air works because every common fault has a thermal or visual signature. A hot spot on a single cell shows up as a bright point confined to one cell, usually a few degrees warmer than its neighbors. A bypass diode failure looks different: a third or half of the module runs hot, because the diode that should isolate a failed substring is stuck open or shorted. A full string outage produces a cold string, a row of modules that show no heat against the warm background of the working strings around it.

Cracked or delaminated modules sometimes show a thermal signature and sometimes do not. When a crack separates a cell electrically, the affected area heats up. Delamination often shows as a diffuse warm patch where the encapsulant has separated from the cell. Soiling patterns follow the shape of the dirt: a uniform warm band across the bottom row points to dust, while a patchy warm spot points to bird droppings. Vegetation shading casts a cool shadow with a hard edge that moves with the sun. Tracker misalignment shows up as a whole row running cooler than adjacent rows, because the panels are pointing away from the sun.

How it works

How a solar farm inspection works

Every inspection starts with the site. We pull the array layout, the inverter and string map, and the module numbering scheme the plant already uses. Then we check airspace. Most utility-scale sites sit in controlled airspace near a substation or transmission corridor, so we file LAANC authorization where required and confirm there are no temporary flight restrictions on the flight day.

Flight planning covers the whole array in a grid that keeps every module in the thermal camera field of view with enough overlap to avoid gaps. We fly at a consistent altitude above the panels so the ground sample distance stays uniform across the site. Capture conditions matter: we schedule the flight for the middle of the day when irradiance is high enough that faults are thermally visible, and we avoid cloudy or windy days that suppress the thermal contrast.

Back in the office we map every thermal finding back to its position in the array. Each flagged module is tied to its row, table, and string using the plant own numbering, so an O&M crew can walk straight to the module without re-surveying the block.

Capture conditions

Why capture conditions matter

Aerial thermal solar inspection only works when the modules are producing enough power to heat the faults above the background. That requires a minimum irradiance level, generally above 600 W/m², and clear sun on the array. A flight under thin overcast or late in the afternoon captures a cooler array where a 2°C hot spot blends into the noise. The data from that flight cannot be trusted, and re-flying on a better day costs more than waiting for the right conditions in the first place.

Wind is the other factor. A steady wind above roughly 8 m/s cools the module surface and suppresses the thermal signature of all but the hottest faults. We watch the forecast and the on-site weather station, and we will hold a flight rather than collect data that would under-report the fault count.

Deliverables

What you receive

The deliverable is built around what an O&M crew needs in the field.

  • Array map with fault locations

    A site overview with every flagged module marked. Delivered as a PDF for review and a GeoJSON file for GIS import.

  • Module-level findings list

    A CSV keyed to your plant numbering with row, table, string, module ID, fault type, severity, and a thermal image thumbnail for each entry.

  • Severity classification

    Each finding is rated by severity so a single hot cell is not ranked the same as a dead string. Severity drives the repair order.

  • Prioritized repair list

    A PDF sorted by severity that the crew can work from top to bottom. Thermal images and zoom photos of flagged modules are delivered as JPG with EXIF coordinates. A KML for Google Earth viewing is available on request.

Equipment

We fly the DJI Zenmuse H30T on the Matrice 400 platform for solar panel thermal inspection. The H30T carries a thermal imaging sensor alongside a zoom camera and a laser range finder, which is the combination that makes aerial thermal solar inspection practical at scale. Survey and mapping work uses our Zenmuse L3 LiDAR payload on the same Matrice 400 platform; inspection work uses the H30T thermal and zoom payload.

The thermal sensor is what finds the faults. Its resolution is fine enough to distinguish a single hot cell within a module from the working cells around it, which is the level of detail required for solar panel fault detection across a large array. A coarser thermal sensor would average the heat of several cells together and bury a single-cell hot spot in the average.

The zoom camera is what confirms the finding. Once the thermal sensor flags a module, we bring the zoom camera onto it and capture a close visual image. A hot spot that lines up with a visible crack, a burn mark, or a delamination bubble goes into the report as a confirmed defect with both images attached. The laser range finder fixes the distance to the module, which keeps the position mapping accurate across the array.

For heat-related defects on electrical equipment beyond the array, see our thermal predictive maintenance inspection. For broader asset work across substations and transmission corridors, see our infrastructure inspection services.

Wind energy

Wind energy site survey and mapping

Wind projects need accurate ground data long before the first turbine arrives. Our wind energy site survey starts with site assessment: topographic surfaces across large parcels that support turbine siting. The model shows terrain, slope, and drainage before layout is fixed, so planners can place machines on ground that drains well and avoids steep cuts that drive earthwork cost. Dense LiDAR returns under crop and light vegetation keep the bare-earth surface usable for early layout studies.

Access road design is next. Wind sites sit on ridgelines and open farmland where crane access roads must handle heavy component transport. Elevation data drives road alignment, grade, and earthwork quantities. We deliver profiles and surfaces the civil team can use to set maximum grades, widen curves for blade trailers, and quantify cut and fill along the haul path. When a proposed alignment crosses a soft swale or steep side slope, the surface makes that conflict visible before equipment is committed.

Crane pad and foundation grading follow the same surface. We compute cut and fill quantities for turbine pads and crane hardstands, then fly again for progress verification during construction. Each pass produces an independent volume check against design so the contractor can confirm pad elevation and hardstand thickness without waiting on a full ground crew walk of every location. Foundation excavations and spoil piles show on the same surface, which helps balance material across the string of pads.

Collection system corridors need the same clarity. We map corridors for underground collection lines and the substation route, capturing centerline, side slopes, and existing features that affect trench and duct bank layout. The corridor surface ties into the same project control as the pads and roads, so electrical and civil packages share one map. Crossing points with access roads and pad edges are easy to mark in one coordinate frame.

Progress tracking closes the loop. Recurring flights give independent earthwork quantities across sites spanning thousands of acres. Construction managers compare successive surfaces to see how much material moved, where pads lag design, and which road segments still need grade work. Turnaround stays in the same 3 to 7 business day window we use on other mapping projects, so weekly or biweekly flights can feed the schedule. We survey and map wind sites for topography, roads, pads, corridors, and progress. We do not claim turbine blade inspection or close-range turbine inspection.

Aerial drone survey of a wind energy site with turbines across rolling farmland
FAQ

Frequently asked questions

Does the plant have to stop production during the flight?

No. We fly with the array energized and producing. The inspection depends on the modules generating power and heat, so shutting the plant down would defeat the purpose. We coordinate with site operations on access and keep the drone clear of inverters and personnel.

How many megawatts can you cover in a day?

Coverage depends on array layout, module density, and how many flights the battery sets allow between swaps. On a typical utility-scale site with contiguous blocks, a single crew covers roughly 30 to 50 MW per day. Sites with scattered blocks or long transit distances between arrays run slower.

How do findings map to our module numbering?

We build the flight plan from your array layout and string map before we fly. Each thermal finding is tagged to its row, table, string, and module position using the numbering your plant already uses, so the findings list drops into your CMMS without a translation step.

How often should an array be inspected?

Most asset managers we work with fly a full aerial thermal solar inspection once a year, with a follow-up on any blocks that showed a high fault count. Newer plants under warranty often get an inspection in the first year to establish a baseline. Sites with recurring soiling or vegetation issues may benefit from a second pass during the growing season.

How do the results support a warranty claim against a module manufacturer?

The report ties each flagged module to its position and pairs the thermal image with a zoom photo of the visible defect. A hot spot that corresponds to a visible crack or burn mark is documented evidence of a module-level defect, which is what a manufacturer warranty process generally requires. We deliver the images and the findings list in formats you can submit directly.

What deliverables do you provide for a wind energy site survey?

Wind site work produces topographic surfaces, contours, and classified point clouds for turbine siting and layout. We also deliver access road profiles and grade checks, cut and fill quantities for crane pads and foundations, corridor mapping for collection lines and the substation route, and progress surfaces when you need recurring earthwork verification. Files ship as LAS or LAZ, GeoTIFF DEM and DSM, contours, and CAD-ready DWG or DXF on the project coordinate system you specify. We survey and map the site. We do not perform turbine blade inspection or close-range turbine inspection.

Can you survey wind sites that span thousands of acres?

Yes. Utility-scale wind parcels often cover thousands of acres across ridgelines and open farmland. We break the site into flight blocks, control the network with RTK GNSS, and process a continuous surface so turbine pads, roads, and collection corridors share one coordinate frame. Recurring flights give independent earthwork quantities as construction moves across the full footprint, without waiting on ground crews to walk every pad.

Ready to schedule an array inspection or wind site survey? Request a quote and we will plan the flight against your layout and project control.

Protect your investment

Catch array faults early and keep wind construction on grade.

Contact us today for a free quote on solar inspection or wind site mapping.

Request a quote

Based in Kansas City, working nationwide

The Kansas City metro is our base. Most Missouri and Kansas work sits inside a day's drive, and we mobilize to sites in every other state.

Travel and mobilization are itemized in the quote before you commit, so a project two states away is priced the same way as one across town.

States we serve

These are the states with dedicated service pages. We fly in all fifty.